HYUNDAI WELDING

Geschäftseinführung

ALL PRODUCT

Fülldrahtelektroden

Supershield 11

Selbstschützende Fülldrähte Supershield 11

Type Self-shielded
Industry Steel structure
JIS Z3313 T49 T14-1 N A
EN ISO 17632-B-T49 Y Z T11-1 NO A
KS
AWS A5.20 E71T-11
  • Caution ① This process does not need an external shielding gas.

    ② Use DC(-) polarity.
  • Purpose ① General fabrication

    ② Galvanized steel

    ③ Civil construction
  • Attribute ① All position self-shielded flux cored wire

    ② Single & multi-pass welding of thin plate

Supershield EG-82T

Selbstschützende Fülldrähte Supershield EG-82T

Type Self-shielded
Industry Energy & Power Plants|Steel Fabrication
JIS
EN
KS
AWS A5.26 EG82T-G
  • Caution ① This process does not need an external shielding gas.

    ② Use DC(+) polarity.
  • Purpose ① Storage tank

    ② Pressure vessels
  • Attribute ① Electro gas arc welding (EGW)

    ② Vertical- up, V-groove & Square Butt joint single pass EGW process

    ③ Good impact value at low-temperature

Supershield EG-72T

Selbstschützende Fülldrähte Supershield EG-72T

Type Self-shielded
Industry Energy & Power Plants|Steel Fabrication
JIS
EN
KS
AWS A5.26 EG72T-1
  • Caution ① This process does not need an external shielding gas.

    ② Use DC(+) polarity.
  • Purpose ① Storage tank

    ② Pressure vessels
  • Attribute ① Electro gas arc welding(EGW)

    ② Vertical-up, V-groove & Square Butt joint single pass EGW process
top